53A-336

53A-336 High Voltage Scanner card

ORDERING INFORMATION
53A-336 – High Voltage Scanner card
OPT 1V – Add VXIbus Compatibility
53A-736 – Analog Cable. or
53A-780 – Hooded Connector

• 16 separately controllable 2-wire channels
• Uses relays designed to withstand inrush currents that can occur when switching a mixture of high and low voltage signals
• Maximum switching power of up to 2000VA ac or 150W dc
• Maximum inrush current of 35A ac or dc

The 53A-336 High Voltage Scanner Card provides 16 two-wire channels of high voltage analog signal distribution at a maximum switching rate of 40 channels per second. Up to ten cards (160 channels) can be plugged into a CDSbus™ chassis. Each Scanner Card can be operated independently, or logically connected with any other scanner card in the system.

The 53A-336 uses relays specifically designed to withstand the high inrush currents that can occur when switching a mixture of high and low voltage AC or DC signals. The capacitance of the wiring between the scanner input and the Unit Under Test (UUT) can easily cause instantaneous currents in excess of 10 Amperes when switching from a low voltage channel (less than 10 to 15V) to a high voltage channel (more than 100V). The resulting instantaneous power may damage the typical 10 Watt contacts found in reed relays. The 53A-336 uses relays with an in-rush current rating of 35A.

The output of each Card is routed both to the front edge connector and to the internal analog backplane. The backplane analog bus allows signals to be routed to and from other instruments (such as the 53A-522 DMM) without external wiring. In addition, 53A-336 Scanner Cards can be combined with other CDSbus scanner cards to form a combination high and low voltage switching system.

BITE
Twelve LEDs provide Built-In-Test Equipment (“BITE”) for the Scanner Card. A lit LED indicates that the associated channel is closed.

Specifications
Configuration:
16 relays, 2-pole, form A.
Common Output Bus, 2 lines.

Contacts:
Maximum Switching Power (resistive), 2000VA ac or 150W dc
Maximum Switching Voltage, 230V dc or ac RMS, shielded.
Maximum Switching Current, 5A ac or 5A dc up to 35V dc, 1A dc up to 60V dc, O.5A dc up to 150V dc,
0.4A dc up to 230V dc.
Maximum Inrush Current, 35A ac or dc.
Initial Contact Resistance, less than 200 milliohms.
Final Contact Resistance, less than 1 Ohm (end of relay contact life).

Reed Life:
At least 10^5 operations per channel at rated resistive loads.

Duty:
Continuous.

Scanning Rate:
Random channels selected at greater than 40 channels per second maximum.

Signal Path Specifications (including the effects of the card cage back-plane. Valid at the backplane analog bus connector):
Differential Thermal Offset, less than 10 microvolts.
Single-line Thermal Offset, less than 20 microvolts.
Initial Signal Path Resistance, less than 900 milliohms.
Signal Path Resistance at End of Reed Life, less than l.4 Ohms.

Isolation Impedance (bus resistance switch open):
Closed Channel, less than 20 gigohms high side or low side analog bus to ground.
Open Channel, greater than 20 gigohms any open input to ground.

Isolation Impedance (bus resistance switch closed):
Closed Channel, 500 KOhm high side or low side analog bus to ground.
Open Channel, greater than 20 gigohms any open input to ground.

53A-336-a

Programmed By:
ASCII Characters.

Recommended Cables:
53A-736.
53A-780.

Available Option:
OPT 1V, add VXIbus compatibility.