63B-000

63B-000 NON-CONFIGURED MAINFRAMES

ORDERING INFORMATION
63B-000 – Five-Slot Non-Configured Mainframe

• Five Function Slots (63B Series), Six Function Slots (64B Series)
• Portable, low Profile
• Optional Rack Slides
• Suitable for OEM applications
• Typically used for sparing

NON-CONFIGURED MAINFRAME
The 63B-000 and 64B-000 non-configured mainframes include the power supply, but do not include Communications, Control, Chaining or Function cards or cables. They are primarily ordered for sparing or replacements. The 63B-013 and 64B-014 mainframes (no power supply) also may be ordered separately.

Specifications
Plug-in Card Positions:
8 positions total.

Cooling:

Built-in forced air cooling.
Typical temperature rise, 7°C or less, intake to exhaust.

Temperature, Ambient
– 10°C to +55°C operating,
– 40°C to +85°C storage.

Dimensions:
17.00″ wide, 5.219″ high, 21.00″ deep. (431.8mmx 132.6 mm x 533.4 mm).
Mounts in standard 19″ NEMA equipment rack with optional rack slides.

Dimensions, Shipping:
21.25″ wide. 9.75″ high, 29.375″ deep.

Weight
24 lbs.

Weight Shipping:
39 lbs.

Output Power Budget per function slot) :
2.5A at 5V DC.
250 mA at +15V DC.
250 mA at -15V DC.

Power Supplies:
Internal by +5V and ± 15V power supplies.

External Power:
The 63B and 63B may be driven from external power if desired.
Contact factory for details.

Power:
90 to 132V ac. 180 to 264V ac (switch-selectable). 47 to 440 Hz, 250 VA maximum.

In-rush (cold start):
30A at 230V for 1/2 cycle.
15A at 115V for 1/2 cycle.

Power Out
175W max continuous DC power out.
225W peak DC power out.

Hardware Provided
63B-013 Mainframe:
41550-63000 Internal Power Supply.